MCS Two-in Four-out Oil-Cooled Charging Connector 1500A
Product Overview
WOER-MCS-C-DC1500-01-LC1 Liquid-cooled charging connector is designed for rapid charging of electric vehicles (EVs) with direct current (DC) through the vehicle connector, installed on electric vehicle charging stations (EVSE). The power cable of the liquid-cooled charging connector employs an immersion cooling solution using dimethicone as the cooling medium. Through forced cooling, heat generated by the cable is dissipated, enabling smaller-cross-section cables to carry higher currents.
Product Model
The interface dimensions comply with IEC DTS 63379-2026 standards, with a rated current of 1500A and voltage of 1500V. Product model: WOER-MCS-C-DC1500-01-LC1.
Product Technical Parameters
| Rated voltage | 1500V |
|---|---|
| Rated current | 1500A(Constant current) |
| Withstand voltage | 4000V AC /min |
| Insulation resistance | At normal temperature conditions ≥500MΩ;Compliant with GB/T11918.1-2014 under humid and hot conditions |
| temperature sensors types | NTC 10K / PT1000 |
| Temperature sensor intervention value | 90℃ |
| Insertion and extraction lifespan | 10,000 insertion and extraction cycles(no-load) |
| Operating ambient temperature | -30℃~50℃ |
| Flame retardant rating | UL 94-V0 |
| Conductor specifications | 2*50mm²(DC+/DC-) |
| Cable color | Black |
| cable outer diameter | Φ46±1.5mm |
| Operating altitude | ≤2000m |
| Plastic material | Thermoplastic |
| Terminal material | T2 Pure Copper/Brass |
| Terminal surface treatment | silver plating |
| Connector tip protection rating | Coupling status: IP55/Connector body: IP67 |
| Cooling medium | Shell E4 |
| Insertion and extraction force | ≤100N |
| Working flow rate | 2-6LPM/25°C |
| Working pressure of liquid cooling system | 0.6MPa |
| Maximum allowable pressure of liquid cooling connector | 0.7MPa |
| Cable outer sheath material | TPU |
| Cable bending radius | >6D |
| Cable structure | 4×50mm²+1×25mm²+P(2×0.75mm²)+2×1.5mm²+6×0.75mm² |
Product Specification
Need a Custom Configuration?
Tell us your rated current, connector standard and cable length — our engineers will propose the right solution.