PRODUCT SPECIFICATIONS
Liquid-cooling Cables

Explore the overview, technical parameters and dimension drawings of this WOER charging solution.

CCS Type 2 DC Charging Connector 500A

Product Overview

WOER-CCS2-C-DC500A-01-LC1 Liquid-Cooled Charging Connector is designed for DC fast charging of electric vehicles (EVs) via vehicle inlet, and is installed on Electric Vehicle Supply Equipment (EVSE). The power cable and cooling medium of Liquid-cooled charging connector adopt a direct-contact cooling solution, with insulating oil as the dielectric coolant. Heat generated by the cable is dissipated through forced circulation, enabling reduced cross-sectional cables to carry higher currents.

Product Model

CCS Type 2 DC Charging Connector, compliant with IEC 62196-1:2022 and IEC 62196-3:2022., integrated temperature sensors for real-time thermal monitoring. Rated Current: 500A; Rated Voltage: 1000V DC; Model: WOER-CCS2-C-DC500A-01-LC1

Product Technical Parameters

Rated Voltage1000V Max.
Rated Current500A Max. (constant current)
Peak Current600A Max.
Withstand Voltage3500V AC/min
Insulation Resistance≥500MΩ(Ambient);Complies with IEC 62196-1 under damp heat conditions
Liquid Cooling System Protection RatingPump, Fan: IP54 Main Assembly: No IP rating
Insertion/Extraction Force≤100N
Mating Cycles10,000 cycles(no-load)
Operating Temperature-30℃~40℃
Flame Retardant GradeUL 94-V0
Conductor Specifications35mm²(DC+/DC-)
Cable ColorBlack
Cable Outer DiameterØ33.5±1mm
Cable Jacket MaterialTPU
Cable Bend Radius6D
Cable Length5.5m Max/8m Max
CoolantShell E4/ Fuchs 8025
Operating Altitude≤2000m
Plastic MaterialThermoplastic
Terminal MaterialT2 Copper/Brass
Terminal Surface TreatmentSilver Plating
Temperature Sensor TypePT1000
Temperature Sensor Intervention Threshold90℃
Connector Protection RatingMated State: IP55/Connector Body:IPX6
Liquid Cooling System Dimensions350mm*374mm*170mm(W*H*L)
Liquid Cooling System Operating Voltage24V DC
Liquid Cooling System Operating Current12A
Liquid Cooling System Power288W
Liquid Cooling System Noise≤60dB
Liquid Cooling System Heat Dissipating2.4kW (50℃)
Coolant Flash Point>200℃
Coolant Dielectric Strength15kV
Operating Flow Rate2.5-6LPM (25℃ Ambient)
Liquid Cooling System Operating Pressure0.7MPa Max
Maximum Allowable Pressure(Liquid-Cooled Charging Connector)0.6MPa Max

Product Specification

CCS Type 2 DC Charging Connector 500A specification

Need a Custom Configuration?

Tell us your rated current, connector standard and cable length — our engineers will propose the right solution.

Get a Quote